Mejores selecciones
Festo Cilindro de aire DNC-100-125-PPV-A-KP
No hay precio en este momento, puede solicitar una cotización
Maritime classification: See certificate
Stroke: 3 mm - 2000 mm
Piston diameter: 100 mm
Type code: DNC
Based on norm: ISO 15552
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Design: Piston: Piston rod: Profile barrel
Position sensing: None: For proximity sensor
Variants: With end-position locking at both ends: Continuous, hollow piston rod: Monostable pneumatic valve, fitted on left, piston rod extended when not actuated: Monostable pneumatic valve, mounted on right, piston rod retracted when not actuated: With front end-position locking: Temperature range -40 to 80 Celsius Degree: Through piston rod: Piston rod with external hexagon: Constant, slow movement: Bistable pneumatic valve, fitted on left, piston rod retracted when not actuated: Increased service life: Extended external thread piston rod: With anti-twist protection: High corrosion protection: With rear end-position locking: Special thread on piston rod: Bistable pneumatic valve, fitted on right, piston rod retracted when not actuated: Dust protection: Piston rod at one end: Monostable pneumatic valve, mounted on left, piston rod retracted when not actuated: Clamping unit on the piston rod: Heat-resistant seals max. 120Celsius Degree: Monostable pneumatic valve, fitted on right, piston rod extended when not actuated: Internal thread on piston rod: Low friction: Extended piston rod
Protection against torsion/guide: Square piston rod
Operating pressure: 0.12 bar - 12 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
ATEX category for dust: II 2D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 1 (ATEX): Zone 2 (ATEX): Zone 22 (ATEX): Zone 21 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 3 - High corrosion stress: 2 - Moderate corrosion stress
Ambient temperature: -40 to 120 Celsius Degree
Impact energy in the end positions: 1.2 J
Max. torque for protection against rotation: 3 Nm
Theoretical force at 6 bar, retracting: 4418 N
Theoretical force at 6 bar, advancing: 4418 N - 4712 N
Type of mounting: With internal thread: With accessories
Pneumatic connection: G1/2
Note on materials: RoHS-compliant
Cover material: Coated: Die-cast aluminum
Material of cylinder barrel: Wrought aluminum alloy: Smooth anodized
Stroke: 3 mm - 2000 mm
Piston diameter: 100 mm
Type code: DNC
Based on norm: ISO 15552
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Design: Piston: Piston rod: Profile barrel
Position sensing: None: For proximity sensor
Variants: With end-position locking at both ends: Continuous, hollow piston rod: Monostable pneumatic valve, fitted on left, piston rod extended when not actuated: Monostable pneumatic valve, mounted on right, piston rod retracted when not actuated: With front end-position locking: Temperature range -40 to 80 Celsius Degree: Through piston rod: Piston rod with external hexagon: Constant, slow movement: Bistable pneumatic valve, fitted on left, piston rod retracted when not actuated: Increased service life: Extended external thread piston rod: With anti-twist protection: High corrosion protection: With rear end-position locking: Special thread on piston rod: Bistable pneumatic valve, fitted on right, piston rod retracted when not actuated: Dust protection: Piston rod at one end: Monostable pneumatic valve, mounted on left, piston rod retracted when not actuated: Clamping unit on the piston rod: Heat-resistant seals max. 120Celsius Degree: Monostable pneumatic valve, fitted on right, piston rod extended when not actuated: Internal thread on piston rod: Low friction: Extended piston rod
Protection against torsion/guide: Square piston rod
Operating pressure: 0.12 bar - 12 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
ATEX category for dust: II 2D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 1 (ATEX): Zone 2 (ATEX): Zone 22 (ATEX): Zone 21 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 3 - High corrosion stress: 2 - Moderate corrosion stress
Ambient temperature: -40 to 120 Celsius Degree
Impact energy in the end positions: 1.2 J
Max. torque for protection against rotation: 3 Nm
Theoretical force at 6 bar, retracting: 4418 N
Theoretical force at 6 bar, advancing: 4418 N - 4712 N
Type of mounting: With internal thread: With accessories
Pneumatic connection: G1/2
Note on materials: RoHS-compliant
Cover material: Coated: Die-cast aluminum
Material of cylinder barrel: Wrought aluminum alloy: Smooth anodized
Las personas que compraron este artículo también vieron
Festo Cilindro de aire ADNGF-50-10-P-A
US$260.77
Festo Cilindro de aire DGSL-12-30-PA
US$784.22
Festo Cilindro de aire DNG-100-320-PPV-A
US$1299.40
Festo Cilindro de aire DSNU-40-50-PPS-A
US$166.51
SIEMENS Actuator GEB163.1E
US$392.97
Los clientes ven con frecuencia
Carel Válvula de expansión E6VB2ASV00
US$839.00
Mitsubishi Compresor RE277NRAMT
US$389.00
Togami Contactor CLK-25J3
US$79.00
KITA Interruptor M84R-PUR-5M
US$19.23
PANASONIC Condensador 16V 560UF
US$5.38
Schneider Disyuntor A9F19240
US$332.00
PIZZATO Interruptor NA B100BB-DN0.4
US$615.38
TYCO Relé RTX3-1AT-B048
US$67.69
Publicaciones relacionadas recientes
-
08/08/2023
Método de cálculo del peso por metro de tubo de cobre para aire acondicionado
Método de cálculo del peso por metro de tubería de cobre para aire acondicionado.
-
06/27/2023
Principio de funcionamiento del compresor frigorífico, esquema eléctrico, estructura
El componente principal del refrigerador es el compresor. Si un frigorífico no está equipado con un compresor de buena calidad y tecnología no puede ser un buen frigorífico.
-
03/10/2024
Todo lo que debe saber sobre el embrague magnético del compresor de CA del coche
Este artículo presenta los componentes del embrague magnético del compresor y su principio de funcionamiento, así como varios parámetros importantes. Además, también le brindamos algunas experiencias sobre cómo lidiar con la quema de los embragues del compresor del aire acondicionado.
-
01/08/2024
¿Por qué vibra el servomotor?
¿En qué casos vibrará un servomotor? ¿Qué pasa si el servomotor vibra? ¿Cómo podemos solucionar los problemas causados por la vibración? Este artículo explicará varias razones para esto.
-
07/29/2023
Compresor Scroll Vs. Compresor rotativo para CA
El compresor scrollue inventado en 1905 por el francés Copeland. Creó la compañía Copeland en los Estados Unidos, donde se utilizan principalmente acondicionadores de aire de agua
-
12/05/2023
Principios y diferencias de los transmisores de 2, 3 y 4 hilos
Los transmisores de 2, 3 y 4 hilos se refieren a transmisores cuyas salidas son señales analógicas de corriente CC.
-
05/19/2022
17 fabricantes de compresores centrífugos, en el mundo. ¿cuántos conoce?
En la última década, en un contexto de globalización económica y feroz competencia, la industria de fabricación de compresores centrífugos también ha experimentado continuas fusiones, adquisiciones y reorganizaciones.
-
08/04/2023
Aire acondicionado Mitsubishi vs Panasonic
El verano es tan difícil de pasar que las personas sin aire acondicionado son como peces fuera del agua. Es fundamental elegir un buen aire acondicionado.
-
02/17/2024
Método de cableado del relé PTC de nevera
El relé PTC (coeficiente de temperatura positivo) está conectado directamente en serie con el devanado secundario (devanado de arranque) y en paralelo con el devanado principal del motor.
-
11/18/2023
Transmisores Rosemount Series 1151, 2088, 2051, 3051CA, 3051S y sus diferencias
El transmisor de presión Rosemount es un tipo de transmisor de presión general. Está fabricado según la ley de inducción electromagnética y la norma JB/T9248-1999.