Mejores selecciones
1/1
Chint Disyuntor NM1-630H/3300
No hay precio en este momento, puede solicitar una cotización
¡El Chint Circuit Breaker es de alta calidad!
¡El rated limit short circuit breaking capacity (ka) is 400v/690v 65/10
¡El rated running short circuit breaking capacity (ka) is 400v/690v 32.5/5
Maintainable mechanical life (times) 10000
Electrical life AC400V (times) 2000
Number of poles 3 4
Flying arc distance (mm) ≤100
¡El rated isolation voltage of the circuit breaker is 800 V (500V for Type 63), which is suitable for AC 50Hz
and rated working voltage
To 690 v (400V for type 63) and rated working current from 10A to 1250A, it is used to distribute electric
energy and protect lines and power equipment from overload, short circuit, undervoltage and other faults.
At the same time, it can also be used as protection for infrequent starting and overload, short circuit
and undervoltage of motor.
¡El circuit breaker has the characteristics of small size, high breaking and short arcing, and is an ideal
product for users.
Circuit breakers can be installed vertically (i.e. vertically) or horizontally (horizontally).
¡El product has isolation function.
Type a n pole is not equipped with overcurrent tripping element, and n pole is always on, which is not
closed with other three poles;
B-type N-pole is not equipped with overcurrent tripping element, and N-pole is combined with other three-poles;
(N poles close first and then divide);
In this series, the three-pole products with shell frame grades from 63a to 250A, the four-pole products with
125A and 250a, and the two-pole products with 125A and 250A H have transparent covers, which can observe the
internal operation of the products at any time.
normal working condition
Ambient air temperature
¡El upper limit of ambient air temperature is+40℃;
¡El lower limit of ambient air temperature is-5℃;
¡El average value of ambient air temperature within 24h shall not exceed +35℃.
Elevation: the elevation of the installation site shall not exceed 2000m.
Atmospheric conditions:
¡El atmospheric relative humidity shall not exceed 50% when the ambient air temperature is +40℃; It can have
higher relative humidity at lower temperature; ¡El monthly average maximum relative humidity in the wettest
month is 90%, and the monthly average minimum temperature in this month is +25℃, taking into account the
condensation on the product surface due to temperature change.
Pollution grade: the pollution grade is Grade 3.
NM1- 125 H P / 3 3 10 2 T 100A
NM1-: Type characteristics NM1 plastic case circuit breaker
125: rated current codes of shell frame level 63A, 125A, 250A, 400A, 630A, 800A and 1250A
H: breaking capacity characteristic code s standard type h higher type r current limiting type
P: operation mode code handle direct operation no code p electric operation z rotating handle operation
/
3. Number of poles 2 poles 3 poles 4 poles
3: name of release 2 electromagnetic release 3 compound release
10: attachment 00 has no attachment
08 alarm contact
10 shunt trip
20 auxiliary contacts
30 Undervoltage Release
40 shunt tripping device,
Auxiliary contact
50 shunt tripping device,
Undervoltage release device
60 Two sets of auxiliary contacts
70 auxiliary contacts,
Undervoltage release device
18 shunt tripping device,
Alarm contact
28 auxiliary contacts,
Alarm contact
38 under-voltage release,
Alarm contact
48 shunt tripping device,
Auxiliary contact,
Alarm contact
78 auxiliary contacts,
Undervoltage release,
Alarm contact
Special for 10Y prepaid meters
release
2: Use No.2 motor protection for power distribution
T: No code transparent cover of conventional products is indicated by "T"
100A: rated current (A) 10, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 160, 180, 200, 225, 250, 315, 350, 400, 500, 400
Example: NM1-125SP/33102 indicates NM1 type plastic shell type circuit breaker, with shell frame grade current
of 125A, breaking capacity of standard type, electric operation, 3 poles, compound trip,
With shunt trip for motor protection. Selection, installation and use shall conform to the product instruction
manual or relevant national standards.
Note: ¡El N-pole type of 4P circuit breaker is divided into A-type and B-type, but it is not indicated that the
default is B-type
¡El rated limit short circuit breaking capacity (ka) is 400v/690v 65/10
¡El rated running short circuit breaking capacity (ka) is 400v/690v 32.5/5
Maintainable mechanical life (times) 10000
Electrical life AC400V (times) 2000
Number of poles 3 4
Flying arc distance (mm) ≤100
¡El rated isolation voltage of the circuit breaker is 800 V (500V for Type 63), which is suitable for AC 50Hz
and rated working voltage
To 690 v (400V for type 63) and rated working current from 10A to 1250A, it is used to distribute electric
energy and protect lines and power equipment from overload, short circuit, undervoltage and other faults.
At the same time, it can also be used as protection for infrequent starting and overload, short circuit
and undervoltage of motor.
¡El circuit breaker has the characteristics of small size, high breaking and short arcing, and is an ideal
product for users.
Circuit breakers can be installed vertically (i.e. vertically) or horizontally (horizontally).
¡El product has isolation function.
Type a n pole is not equipped with overcurrent tripping element, and n pole is always on, which is not
closed with other three poles;
B-type N-pole is not equipped with overcurrent tripping element, and N-pole is combined with other three-poles;
(N poles close first and then divide);
In this series, the three-pole products with shell frame grades from 63a to 250A, the four-pole products with
125A and 250a, and the two-pole products with 125A and 250A H have transparent covers, which can observe the
internal operation of the products at any time.
normal working condition
Ambient air temperature
¡El upper limit of ambient air temperature is+40℃;
¡El lower limit of ambient air temperature is-5℃;
¡El average value of ambient air temperature within 24h shall not exceed +35℃.
Elevation: the elevation of the installation site shall not exceed 2000m.
Atmospheric conditions:
¡El atmospheric relative humidity shall not exceed 50% when the ambient air temperature is +40℃; It can have
higher relative humidity at lower temperature; ¡El monthly average maximum relative humidity in the wettest
month is 90%, and the monthly average minimum temperature in this month is +25℃, taking into account the
condensation on the product surface due to temperature change.
Pollution grade: the pollution grade is Grade 3.
NM1- 125 H P / 3 3 10 2 T 100A
NM1-: Type characteristics NM1 plastic case circuit breaker
125: rated current codes of shell frame level 63A, 125A, 250A, 400A, 630A, 800A and 1250A
H: breaking capacity characteristic code s standard type h higher type r current limiting type
P: operation mode code handle direct operation no code p electric operation z rotating handle operation
/
3. Number of poles 2 poles 3 poles 4 poles
3: name of release 2 electromagnetic release 3 compound release
10: attachment 00 has no attachment
08 alarm contact
10 shunt trip
20 auxiliary contacts
30 Undervoltage Release
40 shunt tripping device,
Auxiliary contact
50 shunt tripping device,
Undervoltage release device
60 Two sets of auxiliary contacts
70 auxiliary contacts,
Undervoltage release device
18 shunt tripping device,
Alarm contact
28 auxiliary contacts,
Alarm contact
38 under-voltage release,
Alarm contact
48 shunt tripping device,
Auxiliary contact,
Alarm contact
78 auxiliary contacts,
Undervoltage release,
Alarm contact
Special for 10Y prepaid meters
release
2: Use No.2 motor protection for power distribution
T: No code transparent cover of conventional products is indicated by "T"
100A: rated current (A) 10, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 160, 180, 200, 225, 250, 315, 350, 400, 500, 400
Example: NM1-125SP/33102 indicates NM1 type plastic shell type circuit breaker, with shell frame grade current
of 125A, breaking capacity of standard type, electric operation, 3 poles, compound trip,
With shunt trip for motor protection. Selection, installation and use shall conform to the product instruction
manual or relevant national standards.
Note: ¡El N-pole type of 4P circuit breaker is divided into A-type and B-type, but it is not indicated that the
default is B-type
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo buscar productos en el sitio web?
Responder: Puede utilizar la barra de búsqueda ubicada en la parte superior del sitio web para ingresar palabras clave y encontrar los productos deseados. Alternativamente, puede navegar a través de diferentes categorías y filtrar opciones para limitar su búsqueda.
- Consulta: ¿Admiten envíos internacionales?
Responder: Sí, admitimos envíos internacionales. Puede seleccionar la opción de envío internacional y proporcionar la dirección de envío correspondiente durante el proceso de pago. Tenga en cuenta que el envío internacional puede requerir tarifas y tiempo adicionales.
- Consulta: ¿Cómo puedo verificar el estado de mi artículo pendiente?
Responder: Para verificar el estado de su artículo pendiente, comuníquese con nuestro equipo de servicio al cliente. Le proporcionarán la información más reciente sobre la disponibilidad y la fecha estimada de envío del artículo.
Comentarios
- U
Usuario anónimo
25/11/2022
Chint Disyuntor NM1-630H/3300¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Chint Disyuntor NM1-630H/3300
No hay precio en este momento, puede solicitar una cotización
Las personas que compraron este artículo también vieron
Siemens Disyuntor 5SL6210-7CC
US$31.25
TRIAD Transformador FP40-300
US$51.55
CHINT Contactor CJX2-1810
US$177.84
Ferraz Shawmut Fusible PC30UD69V400A
US$134.62
LG LS Relé GMP22-3P 1.5A
US$98.08
VISHAY Resistor LTO030F10001JTE3
US$7.96
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
Yaskawa Servo Motor SGMJV-C2A3A-SU11
US$793.50
BANDO Belt T5-1000-7
US$14.62
Parker Denison Bomba de paletas T7DDBS-B24-B35-B03-4R00-A5-00
Contacta con nosotros
TOWA SEIDEN Interruptor TSA-B1SA-090
US$358.40
NACHI Cojinete 16004NSE
US$5.00
Puls Fuente de alimentación ML5660.100
US$323.08
Copeland Compresor ZR48K5-TFC-250
Contacta con nosotros
Saginomiya Válvula de expansión SCX-0657DUC
Contacta con nosotros
Copeland Compresor 3DH3F28KE-TFC-201
Contacta con nosotros