Mejores selecciones
1/1
Chint Disyuntor NB1LE-63
No hay precio en este momento, puede solicitar una cotización
¡El Chint Circuit Breaker es de alta calidad!
¡El rated residual inoperative current is 0.5i △ n.
Residual current protection type AC type
Number of poles 1P+N, 2P, 3P, 3P+N, 4P
Type c of instantaneous release
¡El rated short circuit breaking capacity is 6000a (nb1le-63) and 10000a (nb1le-63h)
¡El rated residual on and off capacity is 500a (in = 50a); 630A(In=63A)
Tightening torque 2.0N? m
Electrical life times (times) 2000 cos ф = 0.85 ~ 0.9 Operating frequency in > 25a, 120 times/hour
Mechanical life times (times) 20000 operating frequency in > 25a, 120 times/hour
NB1LE-63□ Residual current operated circuit breaker is suitable for AC 50Hz, rated voltage unipolar
two-wire, bipolar
230V, three-pole, three-pole four-wire, four-pole 400V, rated current to 63A. When people get electric
shock or the power grid leaks,
When the current exceeds the specified value, the residual current operated circuit breaker can
automatically cut off the power supply in a very short time to ensure personal safety
And prevent equipment accidents caused by leakage current.
Residual current operated circuit breakers also have overload and short circuit protection functions,
which can be used to protect the overload and short circuit of lines.
It can also be used for infrequent line switching under normal conditions.
Impulse voltage resistance of insulation:
A. the impulse voltage with a peak value of 6000V can be borne between the poles connected together and the neutral pole;
B. each pole is connected with the neutral pole and can bear the impulse voltage with the peak value of 8000V between the pole and the metal bracket.
¡El residual current operated circuit breaker can withstand the impact current with a peak current of 200A, and does not cause misoperation.
Elevation: ≤2000m.
¡El rated residual inoperative current is 0.5i △ n.
Residual current protection type AC type
Number of poles 1P+N, 2P, 3P, 3P+N, 4P
Type c of instantaneous release
¡El rated short circuit breaking capacity is 6000a (nb1le-63) and 10000a (nb1le-63h)
¡El rated residual on and off capacity is 500a (in = 50a); 630A(In=63A)
Tightening torque 2.0N? m
Electrical life times (times) 2000 cos ф = 0.85 ~ 0.9 Operating frequency in > 25a, 120 times/hour
Mechanical life times (times) 20000 operating frequency in > 25a, 120 times/hour
NB1LE-63□ Residual current operated circuit breaker is suitable for AC 50Hz, rated voltage unipolar
two-wire, bipolar
230V, three-pole, three-pole four-wire, four-pole 400V, rated current to 63A. When people get electric
shock or the power grid leaks,
When the current exceeds the specified value, the residual current operated circuit breaker can
automatically cut off the power supply in a very short time to ensure personal safety
And prevent equipment accidents caused by leakage current.
Residual current operated circuit breakers also have overload and short circuit protection functions,
which can be used to protect the overload and short circuit of lines.
It can also be used for infrequent line switching under normal conditions.
Impulse voltage resistance of insulation:
A. the impulse voltage with a peak value of 6000V can be borne between the poles connected together and the neutral pole;
B. each pole is connected with the neutral pole and can bear the impulse voltage with the peak value of 8000V between the pole and the metal bracket.
¡El residual current operated circuit breaker can withstand the impact current with a peak current of 200A, and does not cause misoperation.
Elevation: ≤2000m.
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo ver el tamaño y las especificaciones de un producto?
Responder: En la página de detalles del producto, puede encontrar información detallada sobre el tamaño y las especificaciones, incluidas tablas de tamaños, medidas específicas y más, para ayudarlo a seleccionar el producto correcto.
- Consulta: ¿Cómo puedo rastrear mi pedido?
Responder: Una vez que se envíe su pedido, recibirá un correo electrónico de confirmación con información de seguimiento. Puede utilizar esta información para realizar un seguimiento de su pedido a través del sitio web del proveedor de logística.
- Consulta: ¿Ofrecéis servicios de instalación para determinados productos?
Responder: Desafortunadamente, no brindamos directamente servicios de instalación de productos. La disponibilidad de los servicios de instalación generalmente se menciona en la página del producto. Si realmente necesita ayuda con la instalación, comuníquese con nuestro equipo de servicio al cliente para obtener información y arreglos más detallados. Le brindaremos asistencia activamente .
Comentarios
- U
Usuario anónimo
25/11/2022
Chint Disyuntor NB1LE-63¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Chint Disyuntor NB1LE-63
No hay precio en este momento, puede solicitar una cotización
Las personas que compraron este artículo también vieron
Siemens Disyuntor 5SL6320-7CC
US$62.50
EATON Transformador STI0,16(400/24)
US$175.44
TENGEN Contactor TGC1-0610 380V
US$17.69
ABB Fusible 3HNP033842
US$47.14
TWIDEC Relé TH3-60DA/49a
US$120.00
EPCOS Resistor B59603B1120B157
US$1.54
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
HIWIN Guía lineal QHW35HB
US$49.62
Parker Sporlan Válvula de expansión 110387
Contacta con nosotros
Festo Cilindro de aire DNG-63-180-PPV-A
US$350.00
CTMP Bomba magnética CQB65-50-160F
Contacta con nosotros
Schneider Disyuntor HJL36080
Contacta con nosotros
Delta Ventilador AHB1348SHE
Contacta con nosotros
TOYOOKI Bomba de paletas HVP-FC1-L21L-A-G
Contacta con nosotros
Copeland Compresor ZH125KCE-TEE-871
Contacta con nosotros