Parámetro
| Tipo | 3RV1 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 0.4 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 0.28...0.4 A |
| Adecuado para motores de inducción con P | 0.09 kW |
| Liberaciones instantáneas de sobrecorriente | 5.2 A |
| Short-circuit breaking capacidad | 100 kA |
| Peso approx. | 0.235 kg |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S00 for motor protection, CLASS 10 A-release0.28...0.4 A
N-release 5.2 A Screw terminal Standard switchingcapacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 - +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.28 - 0.4
operating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value0.4 A
operating current
at AC-3 at 400 V rated value 0.4 A
operating power at AC-3
at 230 V rated value 60W
at 400 V rated value90 W
at 500 V rated value180 W
at 690 V rated value180 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 5.2 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value0.4 A
at 600 V rated value0.4 A
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V None required
at 500 V None required
at 690 V None required
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Circuit breaker size S00 for motor protection, CLASS 10 A-release0.28...0.4 A
N-release 5.2 A Screw terminal Standard switchingcapacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 - +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.28 - 0.4
operating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value0.4 A
operating current
at AC-3 at 400 V rated value 0.4 A
operating power at AC-3
at 230 V rated value 60W
at 400 V rated value90 W
at 500 V rated value180 W
at 690 V rated value180 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 5.2 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value0.4 A
at 600 V rated value0.4 A
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V None required
at 500 V None required
at 690 V None required
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo buscar productos en el sitio web?
Responder: Puede utilizar la barra de búsqueda ubicada en la parte superior del sitio web para ingresar palabras clave y encontrar los productos deseados. Alternativamente, puede navegar a través de diferentes categorías y filtrar opciones para limitar su búsqueda.
- Consulta: ¿Admiten envíos internacionales?
Responder: Sí, admitimos envíos internacionales. Puede seleccionar la opción de envío internacional y proporcionar la dirección de envío correspondiente durante el proceso de pago. Tenga en cuenta que el envío internacional puede requerir tarifas y tiempo adicionales.
- Consulta: ¿Cómo puedo verificar el estado de mi artículo pendiente?
Responder: Para verificar el estado de su artículo pendiente, comuníquese con nuestro equipo de servicio al cliente. Le proporcionarán la información más reciente sobre la disponibilidad y la fecha estimada de envío del artículo.
Comentarios
- G
Gonzalo
30/07/2024
Siemens Disyuntor 3RV1011-0EA10Me encantó el disyuntor Siemens 3RV1011-0EA10. La instalación fue muy fácil gracias al montaje en riel DIN y su tamaño compacto. La curva de disparo C es perfecta para proteger mis circuitos de sobrecargas.ÚtilNo ayuda - J
Josefina
28/07/2024
Siemens Disyuntor 3RV1011-0EA10La calidad de construcción del disyuntor Siemens es excelente. Los materiales son robustos y la fabricación es precisa. El grado de protección IP20 lo hace adecuado para entornos con polvo y humedad.ÚtilNo ayuda - J
Jesús
29/06/2024
Siemens Disyuntor 3RV1011-0EA10El poder de corte de 10 kA me da la tranquilidad de que mis equipos estarán protegidos en caso de cortocircuito. La tensión nominal de 240 V AC es ideal para mis aplicaciones industriales.ÚtilNo ayuda - F
Francisco
11/07/2023
Siemens Disyuntor 3RV1011-0EA10Ordenado con facilidad.ÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV1011-0EA10¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV1011-0EA10
$ 271 .99
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 2
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
ABB Disyuntor 10069819
US$677.35
Siemens Disyuntor 5SY4202-7
US$66.41
AZBIL Transformador S720A200-GHA
US$110.00
Togami Contactor PAK-35H
US$84.62
Aupo Fusible BF216
US$3.30
COSMO Relé KSD203DC2
US$30.77
Schneider Resistor VW3-A58732
US$313.00
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
ENC VFD Frequency Converter EDS1000-4S0037P
Contacta con nosotros
Shimadzu Bomba de engranajes DSG1A32R398
Contacta con nosotros
Festo Cilindro de aire DSBG-250-320-P-N3
Contacta con nosotros
Bristol Compresor H2BG124DBFX
Contacta con nosotros
Allen Bradley PLC 1756-A4
Contacta con nosotros
Nidec Ventilador B34744-58
Contacta con nosotros
DIODES IC Integrated Circuit Chip AP2331SA-7
Contacta con nosotros