Mejores selecciones
1/1
Siemens Disyuntor 3VL1702-1DD33-0AA0
$ 357 .42
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Parámetro
| Tipo | SENTRON VL160X |
| Tipo de disyuntor | Sentron Molded Case Circuit Breakers |
| Clasificación de amperios | 20 A |
| Interrupción | Standard interruption |
| Número de polos | 3 pole |
¡El Siemens Circuit Breaker es de alta calidad!
circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V
AC 3-pole, line protection Electronic Trip Unit TM, LI In=20A, rated
current Ir=16...20A, overload prot. II=300A, short-circuit prot. without
auxiliary release without auxiliary/alarm switch
Model
type of the driving mechanism / motor drive No
design of the overcurrent release TM
General technical data
number of poles 3
size of the circuit-breaker 3VL1
mechanical service life (switching cycles) / typical 20 000
electrical endurance (switching cycles) / typical 10 000
utilization category A
performance class for circuit breaker N
reference code / acc. to DIN 40719 extended
according to IEC 204-2 / acc. to IEC 750
Q
operating frequency / maximum 120 1/s
Voltage
Rated operational voltage Ue / max. 690 V
insulation voltage
rated value 800 V
at AC / rated value 800 V
surge voltage resistance / rated value 8 kV
operating voltage
rated value / maximum 690 V
for main current circuit / at AC / at 50 Hz /
maximum
690 V
for main current circuit / at AC / at 60 Hz /
maximum
690 V
for main current circuit / at DC / maximum 500 V
Protection class
protection class IP IP20
protection function of the overcurrent release LI
Current
continuous current / rated value 20 A
derating temperature / for the rated value of the
continuous current
50 degrees centigrade
adjustable current response value current
of the current-dependent overload release / fullscale value
20 A
of instantaneous short-circuit trip unit / initial
value
300 A
of instantaneous short-circuit trip unit / full-scale
value
300 A
Main circuit
operating frequency
1 / rated value 50 Hz
2 / rated value 60 Hz
operational current
at 40 degrees centigrade / rated value 20 A
at 50 degrees centigrade / rated value 20 A
at 55 degrees centigrade / rated value 18.6 A
at 60 degrees centigrade / rated value 18.6 A
at 65 degrees centigrade / rated value 17.2 A
at 70 degrees centigrade / rated value 17.2 A
Auxiliary circuit
number of CO contacts / for auxiliary contacts 0
number of NC contacts / for auxiliary contacts 0
number of NO contacts / for auxiliary contacts 0
Suitability
suitability for use system protection
Adjustable parameters
adjustable current response value current / of the
current-dependent overload release / initial value
16 A
Product details
product component
trip indicator No
auxiliary switch No
voltage trigger No
undervoltage release No
undervoltage release with leading contact No
product extension / optional / motor drive Yes
Product function
product function
of thermal overload trip unit adjustable
grounding protection No
for neutral conductors / short-circuit and
overload proof
No
overload protection Yes
Short circuit
breaking capacity operating short-circuit current (Ics)
at 240 V / rated value 65 kA
at 415 V / rated value 55 kA
at 500 V / rated value 14 kA
at 690 V / rated value 4 kA
breaking capacity maximum short-circuit current (Icu)
at 240 V / rated value 65 kA
at 415 V / rated value 55 kA
at 440 V / rated value 25 kA
at 480 V / acc. to NEMA / rated value 25 kA
at 500 V / rated value 18 kA
at 600 V / acc. to NEMA / rated value 8 kA
at 690 V / rated value 8 kA
Connections
arrangement of electrical connectors / for main
current circuit
front side
type of connectable conductor cross-sections / for
main contacts
with flexible busbar 12 x 10 mm
solid 2.5 ... 95 mm?
finely stranded / with core end processing 2.5 ... 50 mm?
stranded 2.5 ... 95 mm?
type of connectable conductor cross-sections / for
auxiliary contacts
solid 0.75 ... 1.5 mm?
finely stranded / with core end processing 0,75 ... 1.0 mm?
type of electrical connection / for main current circuit box terminal
Mechanical Design
height 157.5 mm
width 104.5 mm
depth 106.5 mm
fastening method fixed mounting
Environmental conditions
ambient temperature / during operation
minimum 0 degrees centigrade
maximum 70 degrees centigrade
ambient temperature / during storage
minimum -40 degrees centigrade
maximum 80 degrees centigrade
Certificates
certificate of suitability IEC, standard switching capacity (N)
reference code
acc. to DIN EN 61346-2 Q
circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V
AC 3-pole, line protection Electronic Trip Unit TM, LI In=20A, rated
current Ir=16...20A, overload prot. II=300A, short-circuit prot. without
auxiliary release without auxiliary/alarm switch
Model
type of the driving mechanism / motor drive No
design of the overcurrent release TM
General technical data
number of poles 3
size of the circuit-breaker 3VL1
mechanical service life (switching cycles) / typical 20 000
electrical endurance (switching cycles) / typical 10 000
utilization category A
performance class for circuit breaker N
reference code / acc. to DIN 40719 extended
according to IEC 204-2 / acc. to IEC 750
Q
operating frequency / maximum 120 1/s
Voltage
Rated operational voltage Ue / max. 690 V
insulation voltage
rated value 800 V
at AC / rated value 800 V
surge voltage resistance / rated value 8 kV
operating voltage
rated value / maximum 690 V
for main current circuit / at AC / at 50 Hz /
maximum
690 V
for main current circuit / at AC / at 60 Hz /
maximum
690 V
for main current circuit / at DC / maximum 500 V
Protection class
protection class IP IP20
protection function of the overcurrent release LI
Current
continuous current / rated value 20 A
derating temperature / for the rated value of the
continuous current
50 degrees centigrade
adjustable current response value current
of the current-dependent overload release / fullscale value
20 A
of instantaneous short-circuit trip unit / initial
value
300 A
of instantaneous short-circuit trip unit / full-scale
value
300 A
Main circuit
operating frequency
1 / rated value 50 Hz
2 / rated value 60 Hz
operational current
at 40 degrees centigrade / rated value 20 A
at 50 degrees centigrade / rated value 20 A
at 55 degrees centigrade / rated value 18.6 A
at 60 degrees centigrade / rated value 18.6 A
at 65 degrees centigrade / rated value 17.2 A
at 70 degrees centigrade / rated value 17.2 A
Auxiliary circuit
number of CO contacts / for auxiliary contacts 0
number of NC contacts / for auxiliary contacts 0
number of NO contacts / for auxiliary contacts 0
Suitability
suitability for use system protection
Adjustable parameters
adjustable current response value current / of the
current-dependent overload release / initial value
16 A
Product details
product component
trip indicator No
auxiliary switch No
voltage trigger No
undervoltage release No
undervoltage release with leading contact No
product extension / optional / motor drive Yes
Product function
product function
of thermal overload trip unit adjustable
grounding protection No
for neutral conductors / short-circuit and
overload proof
No
overload protection Yes
Short circuit
breaking capacity operating short-circuit current (Ics)
at 240 V / rated value 65 kA
at 415 V / rated value 55 kA
at 500 V / rated value 14 kA
at 690 V / rated value 4 kA
breaking capacity maximum short-circuit current (Icu)
at 240 V / rated value 65 kA
at 415 V / rated value 55 kA
at 440 V / rated value 25 kA
at 480 V / acc. to NEMA / rated value 25 kA
at 500 V / rated value 18 kA
at 600 V / acc. to NEMA / rated value 8 kA
at 690 V / rated value 8 kA
Connections
arrangement of electrical connectors / for main
current circuit
front side
type of connectable conductor cross-sections / for
main contacts
with flexible busbar 12 x 10 mm
solid 2.5 ... 95 mm?
finely stranded / with core end processing 2.5 ... 50 mm?
stranded 2.5 ... 95 mm?
type of connectable conductor cross-sections / for
auxiliary contacts
solid 0.75 ... 1.5 mm?
finely stranded / with core end processing 0,75 ... 1.0 mm?
type of electrical connection / for main current circuit box terminal
Mechanical Design
height 157.5 mm
width 104.5 mm
depth 106.5 mm
fastening method fixed mounting
Environmental conditions
ambient temperature / during operation
minimum 0 degrees centigrade
maximum 70 degrees centigrade
ambient temperature / during storage
minimum -40 degrees centigrade
maximum 80 degrees centigrade
Certificates
certificate of suitability IEC, standard switching capacity (N)
reference code
acc. to DIN EN 61346-2 Q
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo cambiar mi dirección de correo electrónico asociada a mi cuenta?
Responder: Para cambiar la dirección de correo electrónico asociada a su cuenta, comuníquese con nuestro equipo de servicio al cliente y proporcióneles la información de verificación necesaria. Ellos le ayudarán a actualizar su dirección de correo electrónico.
- Consulta: ¿Puedo guardar artículos en mi carrito para comprarlos más tarde?
Responder: Sí, puede guardar artículos en su carrito para futuras compras. Al agregar artículos a su lista de deseos o guardarlos en su cuenta, podrá acceder fácilmente a ellos y comprarlos más tarde sin necesidad de buscarlos nuevamente.
- Consulta: ¿Cómo puedo ver la calificación promedio y las reseñas de los usuarios de un producto?
Responder: En la página de detalles del producto, puede ver la calificación promedio y las reseñas de los usuarios. Alentamos a los usuarios a compartir sus experiencias de compra y comentarios sobre los productos, para que pueda comprender mejor las opiniones y sugerencias de otros compradores.
Comentarios
- C
Chenghe Xiao
09/07/2025
Siemens Disyuntor 3VL1702-1DD33-0AA0Ensure it arrives at the right moment without a hitch.ÚtilNo ayuda - P
Phillip Campbell
28/05/2025
Siemens Disyuntor 3VL1702-1DD33-0AA0Nice and user-friendly site!ÚtilNo ayuda - P
Peter Harp
04/11/2024
Siemens Disyuntor 3VL1702-1DD33-0AA0I discovered the perfect match for me.ÚtilNo ayuda - G
Gabriela
07/10/2024
Siemens Disyuntor 3VL1702-1DD33-0AA0Estos chicos lo tenían en stock!!!!ÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3VL1702-1DD33-0AA0¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3VL1702-1DD33-0AA0
$ 357 .42
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Siemens Disyuntor 3VF3111-1FN41-0AA0
US$390.23
Siemens Disyuntor 3RV2021-1BA10
US$238.68
Siemens Disyuntor 5SL6220-7CC
US$38.67
LECIP Transformador GS10M47-ZC
US$529.23
TE Contactor EV200AAANA
US$184.62
Ferraz Shawmut Fusible NH1UD69V63PV
US$123.08
HOYMK Relé SSR-100VA
US$36.92
Panasonic Resistor EXB-Q16P471J
US$1.15
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
CKD Cilindro de aire SCG-00-80B-300-T
Contacta con nosotros
YASKAWA Interruptor PSKU-100R25AV
US$615.38
Copeland Compresor ZB29KQ-PWD-559
Contacta con nosotros
Teco TAIAN VFD Frequency Converter E510-425-HN4-U
Contacta con nosotros
Allen-Bradley Contactor 100-KR09KF10
Contacta con nosotros