Parámetro
| Tipo | 3RV2 |
| Tipo de disyuntor | Motor Protection Circuit Breakers |
| Corriente nominal | 84 |
| Número de polos | 1 pole |
| Rango de ajuste para disparadores de sobrecarga térmica | 65...84 A |
¡El Siemens Circuit Breaker es de alta calidad!
Circuit breaker size S3 for motor protection, Class 20 A-release
65...84 A N-release 1170 A screw terminal Increased switching
capacity 100 kA
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S3
size of contactor can be combined company-specific S3
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 34?W
at AC in hot operating state per pole 11.3?W
insulation voltage with degree of pollution 3 at AC
rated value
1?000?V
surge voltage resistance rated value 8?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 25?000
of auxiliary contacts typical 25?000
electrical endurance (switching cycles)
typical 25?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
65?...?84?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 84?A
operating current
at AC-3
at 400 V rated value 84?A
operating power
at AC-3
at 230 V rated value 22?000?W
at 400 V rated value 45?000?W
at 500 V rated value 55?000?W
at 690 V rated value 75?000?W
operating frequency
at AC-3 maximum 15?1/h
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class Class 20
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 5?kA
at 690 V rated value 3?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 6?kA
response value current
of instantaneous short-circuit trip unit 1?170?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 84?A
at 600 V rated value 84?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 7.5?hp
at 230 V rated value 15?hp
for three-phase AC motor
at 200/208 V rated value 25?hp
at 220/230 V rated value 30?hp
at 460/480 V rated value 60?hp
at 575/600 V rated value 75?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 165?mm
width 70?mm
depth 176?mm
Circuit breaker size S3 for motor protection, Class 20 A-release
65...84 A N-release 1170 A screw terminal Increased switching
capacity 100 kA
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S3
size of contactor can be combined company-specific S3
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 34?W
at AC in hot operating state per pole 11.3?W
insulation voltage with degree of pollution 3 at AC
rated value
1?000?V
surge voltage resistance rated value 8?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 25?000
of auxiliary contacts typical 25?000
electrical endurance (switching cycles)
typical 25?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
65?...?84?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 84?A
operating current
at AC-3
at 400 V rated value 84?A
operating power
at AC-3
at 230 V rated value 22?000?W
at 400 V rated value 45?000?W
at 500 V rated value 55?000?W
at 690 V rated value 75?000?W
operating frequency
at AC-3 maximum 15?1/h
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class Class 20
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 5?kA
at 690 V rated value 3?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 6?kA
response value current
of instantaneous short-circuit trip unit 1?170?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 84?A
at 600 V rated value 84?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 7.5?hp
at 230 V rated value 15?hp
for three-phase AC motor
at 200/208 V rated value 25?hp
at 220/230 V rated value 30?hp
at 460/480 V rated value 60?hp
at 575/600 V rated value 75?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 165?mm
width 70?mm
depth 176?mm
Hacer preguntas
(0/1,200)
- Consulta: ¿Cómo puedo ver el tamaño y las especificaciones de un producto?
Responder: En la página de detalles del producto, puede ver el tamaño y las especificaciones del producto. Por lo general, proporcionamos tablas de tallas detalladas y descripciones de especificaciones para ayudarlo a elegir el producto correcto.
- Consulta: ¿Cómo puedo verificar el estado de mi reclamo de garantía?
Responder: Para verificar el estado de su reclamo de garantía, comuníquese con nuestro equipo de servicio al cliente y proporcióneles los detalles necesarios, como su número de reclamo de garantía o información del pedido. Le ayudarán a seguir el progreso de su reclamo.
- Consulta: ¿Existen restricciones de cantidad mínima de pedido para comprar ciertos productos?
Responder: Sí, para ciertos productos, es posible que existan restricciones de cantidad mínima de pedido. Esto garantiza un procesamiento eficiente y rentabilidad para ambas partes involucradas. Verifique los detalles del producto o comuníquese con nuestro equipo de ventas para obtener información específica sobre las cantidades mínimas de pedido.
Comentarios
- D
David Brightwell
18/04/2025
Siemens Disyuntor 3RV2042-4RB10That's just the most wonderful!ÚtilNo ayuda - E
Elizabeth Mendelman
03/04/2025
Siemens Disyuntor 3RV2042-4RB10CommendableÚtilNo ayuda - P
PHU VUONG
19/02/2025
Siemens Disyuntor 3RV2042-4RB10I'm so glad I took the chance on this product, it's a great choice.ÚtilNo ayuda - E
Estrella
27/04/2024
Siemens Disyuntor 3RV2042-4RB10Arreglaron mi pedido cuando accidentalmente pedí un pedido equivocado. Y aún me lo entregaron a tiempo.ÚtilNo ayuda - U
Usuario anónimo
25/11/2022
Siemens Disyuntor 3RV2042-4RB10¡Todo estuvo bien! No hay problema alguno.ÚtilNo ayuda
Siemens Disyuntor 3RV2042-4RB10
$ 1,265 .00
Haga clic aquí para ver los gastos de envío.
✔ En stock (Puede enviarse en 5-7 días)
Cantidad
MOQ : 1
Pagos

Soporte en línea 24/7
12 meses de garantía para productos nuevos
Garantía de devolución del dinero en 30 días
Gastos de envío
excluidos derechos de aduana e impuestos
--
Total
--
Las personas que compraron este artículo también vieron
Fuji Disyuntor BW100EAG-2P075
US$134.62
Siemens Disyuntor 3RV1031-4DA10
US$686.06
Fuji Disyuntor BC63E1CG-1P002
US$46.54
Eaton Moeller Disyuntor PKZM0-6.3-T
US$109.56
TRIAD Transformador F36-350-C2
US$32.27
Schneider Contactor LC1-D258
US$651.92
BOURNS Fusible MF-R020
US$0.06
TOWARD Relé SIP-1A24DW
US$9.62
Caddock Resistor MP850-100-5%
US$2.70
Los clientes ven con frecuencia
Hitachi Compresor E405DHD-38A2YG
US$1125.00
SEALMASTER Cojinete FC-1510
Contacta con nosotros
NKK Interruptor HS16-2SN
US$48.30
TAKEX Sensor GMR2RPNN
US$138.00
Mitsubishi Compresor RB174GNKC
US$340.00
MGM Motor Eléctrico BM63C4
US$856.00
SKF Cojinete NU 230 ECJ/C3
US$1384.62
Copeland Compresor ZP72KCE-TF5-430
Contacta con nosotros
YUKEN Bomba de paletas PV2R13-12-76-L-RAAA-42
Contacta con nosotros
ATOS Válvula solenoide DHI-0631/2/A/PE24DC
Contacta con nosotros
Omega Caudalímetro FMA-A2315
US$2442.31
BANLMEYD BMD Cojinete NU2326
US$1461.54
Mitsubishi Compresor XB272GTD
US$245.39